JA-120Z Bus back-up booster unit for JA-100
The product is offered as an electronic module with the JA-83PWR power supply unit. We recommend installation in a PLV-CP-L plastic housing. The product is a component of the JABLOTRON 100+ system, is addressable and occupies one position in the system.
- Output current max. 2A
- 2 independent bus output terminal boards - each providing 500 m of bus length
- The galvanic isolation of the output terminals deals with different ground potentials and safety isolation of the bus
- Up to 3 boosters can be arranged in series
- Back-up battery up to 18 Ah
Technical specifications
Mains power (the JA-83PWR power supply) | 90 – 250 V AC |
---|---|
Input power | 50 VA |
Fuse | T1.6 A/250 V, 5 x 20 mm |
Input part | |
Powered from the control panel BUS | 12 V DC (9 … 15 V) |
Current consumption | |
- in standby mode | 10 mA |
- for cable choice | 10 mA |
Output part | |
Output voltage | typically 13.7 V DC |
Maximum ripple | 0.1 Vpp |
Maxmum load current | 2 A |
Galvanically separated | (testing voltage 4 kV) |
General | |
Back-up battery 12 V | 7 – 18 Ah |
Back-up battey type | lead, gel |
Low battery level | ≤ 10.9 V |
Protection againts deep discharging | ≤ 9.7 V |
Maximum time for charging back-up battery | < 72 h/80% C for 18 Ah |
Weight of module PCB | 45 g |
Weight of the JA-83PWR power supply | 360 g |
PCB dimensions | 102 x 66 x 14 mm |
Power supply dimensions | 170 x 80 x 65 mm |
PLV-PC-L plastic housing dimensions | 357 x 297 x 105 mm PLV-PC-L plastic housing is not supplied! |
Classification | security grade 2/environmental class II |
Note: valid for only installation into a PLV-CP-L plastic housing or into another box of a security grade 2 or higher certified device. | |
- according to | EN 50131-1, EN 50131-6 |
- environment | general indoor |
- operational temperature range | -10 to +40 °C |
- operational humidity | 75 % RH, non-condensing |
- certification body | Trezor Test s.r.o. (no. 3025) |
Also complies with | EN 60950-1, EN 50130-4, EN 55022 |